The recommended cleaning interval is every 3,000 rivet installations. If dust is accumulated, it deteriorates the movement of the jaws and may accelerate wear of the jaws and jaw case. To clean the jaws and jaw case follow the steps below. 1. Remove the jaw case. 2. Remove the jaws from the jaw case 3. Clean the jaws with a brush. Remove any metal powder clogged between the teeth 4. Apply supplied grease evenly to the inner jaw case 5. Install the jaws to the jaw case 6. Install the jaw case and reassemble the head assembly 7. Insert rivet into nose piece and remove wiping away any excess grease